We supply cable jelly, and cable filling
compound ( flooding compounds) for the
copper core and fiber optic cable industry. Filling Compound
Specifications
Sr. # |
Characteristics |
Filling Compound |
Flooding Compound |
Paragel
THXO |
Para-Gel |
1. |
Colour |
- |
Doesn't Obscure |
- |
2. |
Specific Gravity @ 27oC |
- |
0.91 +/- 0.02 |
- |
3.
|
Drop
Point oC Min.
|
120 -
150
(to specific requirements) |
85 - 105
(to specific requirements) |
85 - 110
(to specific requirements) |
4. |
Cone
Penetration @ 25oC, mm, Min. |
200 -
400
(to specific requirements) |
35 - 60
(to specific requirements) |
80 - 200
(to specific requirements) |
5. |
Flash Point,
oC, Min. |
230 |
>232 |
200 |
6. |
Volume
Resistance @ 100oC, ohm- CM,
Min. |
0.8 |
1 x 1010 |
- |
7. |
Neutralisation Number, mg KOH/g Max. |
- |
0.05 |
- |
8. |
Viscosity @ 100oC, cSt, Min. |
- |
85 - 105 |
- |
9. |
Stability Test @ 70oC, for 5
days |
Shall
Pass |
No
Separation of Constituents of compound |
No
Separation of Constituents of compound |
10. |
Power Factor @ 23oC, 1 Mhz.,
Max. |
- |
0.0005 |
- |
11. |
Permitivity @ 20oC, 1 Mhz.,
Max |
- |
2.3 |
- |
12. |
Absorption % Max. |
- |
8.0 |
- |
13. |
Acidity mg of KOH |
- |
Neutral |
- |
Download this Jelly
Specifications
Coaxial
Jelly Specifications
Sr. # |
Characteristic |
Specifications |
1. |
Colour |
Light
Yellow |
2. |
Handling |
Easily
Removable |
3. |
Stability @
65oC
/ 5 days |
Passes |
4. |
Toxicity |
Certified
by Indian Institute of Toxicity |
5. |
Drop Point
oC |
100 - 115 |
6. |
Flash Point
(COC)
oC |
220 min |
7. |
Neturalisation No. mg KOH/g |
0.03 |
8. |
Cone
Penetration @ 25oC
(dmm) |
60 - 70 |
9. |
Volume
Resistance @ 100oC/500
VDC, Ohm - cm |
4.40 x 1013 |
10. |
Permitivity
@ 20oC,
1 Mhz |
2.08 |
11. |
Power
Factor @ 20oC,
1 Mhz |
0.0005 |
12. |
OIT @ 190oC,
Cu Pan Minutes |
>/= 30 |
Download Co-axial jelly specifications
The information provided on this page
is, to the best of our knowledge accurate, however, it is subject to change
without prior notice. We assume no liability for the completeness of it or
errors in it. Current and final specifications and datasheets can be
obtained by contacting us
|